Snssw65-I Two-way, double-valve, double-outlet pressure reducing and stabilizing indoor fire hydrant

Product Name: SNSSW65-I Two Way Double-valve double-outlet Pressure Reducing and Pressure Stabilizing Indoor Fire HydrantModel Specification SNSSW65-I Fire HydrantNominal diameter (mm) DN 65Nominal pressure 1.6 MPaPipe thread Rp3Pipe thread depth (mm) 25Height after closing ≤270Center height

Featured Products


Product Name: SNSSW65-I Two Way Double-valve double-outlet Pressure Reducing and Pressure Stabilizing Indoor Fire Hydrant
Model Specification
 
SNSSW65-I Fire Hydrant
Nominal diameter (mm)
 
DN 65
Nominal pressure
 
1.6 MPa
Pipe thread
 
Rp3
Pipe thread depth (mm)
 
25
Height after closing
 
≤270
Center height of water outlet
 
110
The center of the stem is away from the interface
 
≤126
Inlet Pressure
 
0.4 ~ 0.8 MPa
Outlet Pressure0.25 ~ 0.35 MPa
Flow Water (Liter/ second)≥ 5 Liters Water
Applicable medium
 
Water
Indoor Fire Hydran Detail
 
See Bellow Pictures

Snssw65-I Two Way Double-Valve Double-Outlet Pressure Reducing and Pressure Stabilizing Indoor Fire Hydrant
Snssw65-I Two Way Double-Valve Double-Outlet Pressure Reducing and Pressure Stabilizing Indoor Fire Hydrant
Snssw65-I Two Way Double-Valve Double-Outlet Pressure Reducing and Pressure Stabilizing Indoor Fire Hydrant
Snssw65-I Two Way Double-Valve Double-Outlet Pressure Reducing and Pressure Stabilizing Indoor Fire Hydrant
Snssw65-I Two Way Double-Valve Double-Outlet Pressure Reducing and Pressure Stabilizing Indoor Fire Hydrant
Snssw65-I Two Way Double-Valve Double-Outlet Pressure Reducing and Pressure Stabilizing Indoor Fire Hydrant

1. The SNSSW indoor fire hydrant is a product designed according to the GB3445-2005 "Indoor Fire Hydrant" standard, which maintains the characteristics of the SNSS65 indoor fire hydrant, such as rapid opening and closing, reasonable structure and convenient maintenance. On this basis, the decompression and pressure stabilization function is added. No matter the inlet pressure is high or low, the pressure in the pipe network fluctuates and changes, and its outlet pressure can be decompressed and stabilized at the use pressure value.It is suitable for factory workshop office, government, small big schools, Public place and transportation ship.

2. The product is installed in a fire hydrant box in an obvious position of the building, and is used in conjunction with fire hoses and fire hoses. In case of fire, quickly connect the fire hose to the fire hydrant, connect the fire hose to the other end, turn the handwheel, drive the valve flap through the valve stem, turn clockwise to close, and turn counterclockwise to open. The pressure water flows out from the water outlet through the hydrant inlet through the shut-off port of the pressure-reducing and voltage-stabilizing device.

3. When the pressure exceeds 0.4 MPa, the axial force of the outflow water pressure on the end face of the spring seat moves to the outside of the hydrant, and the spring is compressed to generate elastic force until the water pressure decreases to produce a decompression and pressure stabilizing effect.