Vg70 respirator respirator CE certificate hospital ventilator suitable for ICU Vg70 ventilator price

 Product DescriptionSuperior Mobile ICU ventilator• Comprehensive ICU ventilator including BIVENT and PRVC• Compact, big capacity battery, no air compressor, intra-hospital mobility• Flexible device configuration: equipped on a trolley, bed or ceiling pendantCost Effective Solution• Unique metal-base

Featured Products



 
Product Description



Vg70 Breathing Apparatus Respirator CE Certificate Hospital Breathing Machine for ICU Vg70 Ventilators Price
Superior Mobile ICU ventilator
• Comprehensive ICU ventilator including BIVENT and PRVC
• Compact, big capacity battery, no air compressor, intra-hospital mobility
• Flexible device configuration: equipped on a trolley, bed or ceiling pendant
Cost Effective Solution
• Unique metal-based, autoclavable, heated exhalation valve
• Built-in flow sensor, non-consumable design
• Upgradeable ventilation system software, with an available USB port

Patient type :Adult and pediatric patient
Ventilation modes : VCV(A/C)
PCV(A/C)
PRVC(optional)
SIMV(VCV)+PSV
SIMV(PCV)+PSV
SIMV(PRVC)+PSV
SPONT/CPAP+PSV
BIVENT/APRV+PSV(optional)
NIV/CPAP
NIV-T
NIV-S/T
Enhancements :
Apnea ventilation
Lung mechanic
Pressure and Flow trigger
Automatic Tube Compensation (ATC)
Smart suction
Manual breath
Insp/Exp hold
Waveform freeze
Nebulization
Non-invasive ventilation (NIV)
etCO2 measurement
Parameter settings
Ventilation frequency (f)VCV: 1-80/min (adult)
2-80/min (pediatric)
NIV Ventilation frequency (f): 4-20/min (adult)
4-40/min (pediatric)
Inspiratory time (Ti): 0.2-9 s (adult)
0.2-5 s (pediatric)
Tidal volume (VT): 50-2000ml (adult)
20-300ml (pediatric)
Tpause: 0-4 s (adult)
0-2.5 s (pediatric)
Ventilation frequency (f)SIMV:1-40/min
Inspiratory pressure (Pinsp): 5-70 cmH2O
Psupp: 0-70 cmH2O
Psupp NIV: 0 to(50-PEEP )cmH2O
PEEP: 0-35 cmH2O
PEEP in NIV: 2-20 cmH2O
CPAP in NIV: 2-20 cmH2O
Rise time (Slope): 0-2 s
O2 concentration (FiO2): 21%-100%
Trigger sensitivity: 0.5 to 20 L/min(Flow trigger)
-20 to 0 cmH2O (Pressure trigger)
Exp. sensitivity(% of peak flow): 5%-80%
BIVENT
Thigh: 0.2-30 s
Tlow: 0.2-30 s
Phigh: 5-60 cmH2O
Plow: 0-35 cmH2O
Automatic Tube Compensation (ATC)
Inner tube diameter: 5-12mm (adult)
2.5-8mm(pediatric)
Tube type: Endotracheal tube ET
Tracheostomy tube Trach
Degree of compensation:0-100%
Measured values displayed
Airway pressure measurement:
Plateau pressure (Pplat)
Positive end-expiratory pressure (PEEP)
Peak inspiratory pressure (Ppeak)
Mean airway pressure (Pmean)
Min. airway pressure (Pmin)
Flow measurement:
Expiratory minute volume (MVe)
Spontaneous expiratory minute volume (MVespont)
Inspiratory tidal volume (VTi)
Expiratory tidal volume (VTe)
Frequency measurement:
Total respiratory frequency (ftotal)
Spontaneous respiratory frequency (fspont)
O2 measurement:
Inspiratory O2 concentration (FiO2)
CO2 measurement
End-expiratory CO2 concentration (etCO2)
Displayed calculated values
Compliance (C)
Resistance (R)
leakNIV
RSBI
WOB
Tispont
I:E
Vdaw
PEEPi
Tc
Elastance
Curve displays : Airway pressure (t) (Paw) -20 to 100 cmH2O
Flow (t) -180 to 180 L/min
Volume (t) 0 to 3000ml
CO2 (t) 0 to 80 cmH2O
Pressure-Volume loop
Pressure-Flow loop
Flow-Volume loop
Alarms
Expiratory minute volume (MVe) High / Low
Airway pressure (Paw) High / Low
Expiratory tidal volume (Vte) low
PEEP High / Low
Insp. O2 concentration (FiO2) High / Low
(automatic)
End - expiratory CO2 concentration (etCO2) High / Low
Respiratory rate (f) High
Apnea alarm time 10 to 60 seconds, Off
Inspiration duration High
Oxygen sensor failure Yes
O2 supply pressure Low
AC failure Yes
Low battery Yes
Limited battery capacity Yes
Occlusion Yes
CO2 sensor Error/Failure
Leakage out of range Yes
Fan block Yes
Performance data
Control principle:
Electronically driven and electronically controlled
Nebulization: 30min
Suction Oxygen enrichment: Before aspiration of sputum 3 min
Post aspiration of sputum 2min
Base flow: 5-25 L/min
Max flow: 180 L/min
Leakage compensating flow: 60L/min
Operating data
Main power connection: 100V-240V, 50/60Hz
Power consumption:
110-120VAC:2A,200VAC(Ventilator only)
10A(Ventilator plus Auxiliary Outlets)
220-240VAC:1A,200VAC (Ventilator only)
8A(Ventilator plus Auxiliary Outlets)
Gas supply:
O2 gauge pressure 280-600KPa
Language:
Chinese, English, Spanish, Polish, Turkish, Russian
Other languages can be customized.
Physical Specifications
Dimensions(W*D*H):VG70 350mm*460mm*415mm
Cart 547mm*675mm*950mm
Weight: VG70 15kg
Cart 25kg
Diagonal screen size: 12"TFT color touch screen
Input / Output ports: 2 USB ports
Real-time VGA output
1 RJ 45 Ethernet connectors
Nurse call
CO2 port

Detailed Photos


Vg70 Breathing Apparatus Respirator CE Certificate Hospital Breathing Machine for ICU Vg70 Ventilators Price
Vg70 Breathing Apparatus Respirator CE Certificate Hospital Breathing Machine for ICU Vg70 Ventilators Price

Vg70 Breathing Apparatus Respirator CE Certificate Hospital Breathing Machine for ICU Vg70 Ventilators Price

Packaging & Shipping

 

Vg70 Breathing Apparatus Respirator CE Certificate Hospital Breathing Machine for ICU Vg70 Ventilators Price

VG70 Breathing Apparatus Respirator CE Certificate Hospital Breathing Machine For ICU VG70 Ventilators Price 
VG70 Breathing Apparatus Respirator CE Certificate Hospital Breathing Machine For ICU VG70 Ventilators Price 
VG70 Breathing Apparatus Respirator CE Certificate Hospital Breathing Machine For ICU VG70 Ventilators Price 

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours