There are many options for ensuring accurate billing of water used at established industrial customer locations. But how do municipalities or businesses keep track of water availability and use for intermittent applications or movable access points? McCrometer Inc’s Marc Bennett provided insight into how water utilities and industries can efficiently track and allocate water use for billing or internal accounting purposes in such ad hoc applications.

How are fire hydrant meters typically used?

Fire hydrant meters are typically used to document flow capacity at a specific point in a distribution system or to track a cumulative volume of water use over a period of time.

These meters are generally employed for temporary installations or testing in applications where a fire hydrant is the targeted source of water, but they can also be installed in other application environments as needed.

What advantages do fire hydrant flow meters deliver in those applications that other types of meters do not?

Because they come with a standard-size threaded connector for fire hydrants, attachment is quick and easy, so there is no need to customize another style of meter to fit a hydrant application. Although many fire hydrant flow meter applications are for temporary uses, they can also be permanently installed into an application.

What are the most common applications for fire hydrant flow meters?

Testing companies, fire departments, and other municipal entities typically conduct flow tests to determine that each fire hydrant can deliver a minimum rate of flow (gpm) — usually at 20 psi residual pressure — for a duration of two hours. Those tests are based on the hose length used. Fire hydrants that do not have sufficient capacity receive no credit for insurance-rating purposes, although they may be used for limited fire-suppression capability.

How are fire hydrant flow meters used for other industrial applications?

In addition to using fire hydrant flow meters for their own flow testing, municipalities can employ them to document water-use charges to specific cost centers for uncommon applications — such as filling community swimming pools or summer hydrant openings during heat waves.

Municipalities might also lease or lend meters out to construction contractors who have received permits for a volume of water to be used for temporary projects. For example, businesses that receive permits to use hydrant water for tasks such as power washing, street cleaning, or other general construction, dust suppression, or irrigation uses, are typically required to report the amount of water used.

Also, private businesses can take advantage of fire hydrant flow meters to track internal water usage in temporary or on-again/off-again applications downstream from their water-utility meter. Doing so makes it easy to provide a separate cost accounting of the volume of water associated with such special applications. The meter design is suitable for any potable or non-potable water application, but not for wastewater use.

Special industry application uses not related to treated water flowing from a water utility could include withdrawals from surface water or groundwater sources for natural gas fraccing applications. Even when not connected to a traditional hydrant fixture, these easy-to-install meters can make it easier to document the exact volume of water used under permitted allocations, instead of relying upon rough estimations based on tanker truck sizes.

What are some key features to look for when specifying a fire hydrant flow meter for an industrial or commercial application?

While  fire hydrant f l ow meters  are typically not permanently installed, it does pay to consider features that will provide maximum accuracy and reliability for long-term performance. Consider these features that deliver convenient, reliable operation in use to document volume measurements or pressure performance requirements:

For further information, contact AMS Instrumentation & Calibration on 03-9017 8225, e-mail [email protected] or visit www.ams-ic.com.au.

Lauren ‘LJ’ Butler is the Assistant Editor of Utility magazine and has been part of the team at Monkey Media since 2018.

In January 2016, Zinfra was awarded a significant project by Transport for NSW (TfNSW) as part of TfNSW’s Power...

Spoil management is an important consideration on any trenchless pipeline installation to ensure environmental regulations are met through proper...

Smart meter rollouts are happening all over the world, with utilities trying different approaches, technologies and solutions to accomplish...

by James Pearce, Director, ENM Solutions On 1 December 2017, an amendment to the National Electricity Rules by the...

Gaining a competitive advantage relies on the ability to provide real value to customers in a marketplace that offers...

The high stress-crack resistance of Alkadyne® HCR193B – Australia’s first pipe resin classified as PE100 HSCR according to PIPA...

Leading enterprise software company, TechnologyOne, has called on New Zealand’s energy sector to focus on maximising the longevity of...

700 new homes within Clyde North’s new Kilora Estate (VIC) will now be connected to a 13m deep branch...

When Rangitata Diversion Race (RDR) Management decided to improve the visibility...

The implementation of smart water meters in Australian Woolworth’s stores has ...

Recent construction project management software updates will enable improved pro...

Positive air flow pressure and exhaust ventilation systems require highly sensit...

Australian smart monitoring company UtiliOS is offering a customisable Human-Mac...

If you’d like to find out more about us, please get in touch – we’d love to hear from you.

©2022 Utility Magazine. All rights reserved

We're not around right now. But you can send us an email and we'll get back to you, asap.